5.5.5 Cleaning the dry air filter
Change the filter element:
if the filter element or sealing ring is damaged
Attention
if sooty deposits are present
if moist or oily deposits are present
if engine performance reduces or
if the exhaust gas changes colour
minimum once a year
Never operate the engine without air filter element.
1
Remove cover (1).
Carefully remove filter element (2)
B5399018.cdr
– Check filter element (2) for cracks or other damage by holding
against the light or using a lamp.
B5399020.cdr
3
B5399016.cdr
B5399017.cdr
Clean filter cover (1) and housing (3).
Replace filter element or clean appropriate.
2
B5399019.cdr
If there is any dry pollution: Blow out the filter cartridge with dry
air under pressure (max. 5 bar) from the inside outwards, until
no more dust comes out.
Risk of eye injuries! – Wear safety goggles.
Danger
Care refit filter element (2).
Fit cover (1).