3) Turn the knob to select the group to be de-
leted and then press the knob The following
confirmation prompt appears:
Group "Ux" will be
cleared, Continues?
YES
4) To cancel the process, press the button EXIT
To delete the group, press the knob
5) To delete further groups, repeat steps 3 and 4;
to exit all menus, press the button EXIT three
times
4.5.5 REMOSET function
Transferring settings to the transmitters
When the transmission frequencies or the groups
and the transmission channels have been set on
the receiver sections of R-4 / 5, simply press a but-
ton to transfer the settings of the receiver sections
to the corresponding transmitters Always make
sure that
1 no menu is called up on the receiver or on
the transmitter
2 the transmitter is switched on and close to
the receiver (REMOSET transmission range:
approx 10 m)
3 the REMOSET function is not locked or disa-
bled on the transmitter
4 the transmitter and the corresponding receiver
section are set to the same identification num-
ber
5 the batteries of the transmitter are not dis-
charged
– Identification number –
Each pair of transmitter / receiver must have a dif-
ferent identification number (ID no ); this is the
only way to make sure that each transmitter is
supplied with the settings intended The receiver
sections 1 – 4 are preset to the identification num-
bers 1 – 4 Resetting will also reset the receiver
sections to these numbers When further receivers
R-4 / 5 are used, they must be assigned different
identification numbers (e g the second receiver
must be assigned the numbers 5 – 8):
1) Keep the button SETUP pressed to call up
the menu Turn the knob PUSH / CONTROL
to select the receiver section to be changed
24
NO
Fig. 24
(CH1 – 4) Press the knob and then select item
5.Remoset ID
on page 17)
Remoset ID
1
2) Turn the knob PUSH / CONTROL to set the
identification number
3) Press the button SETUP to save the setting
4) Press the button EXIT to go to the highest
menu level; repeat the setting for the other
receiver sections
5) Make sure to set each transmitter to the identi-
fication number of the corresponding receiver
section
– REMOSET transmission –
1 For four transmitters at the same time
Press the button REMOSET (5) During the
REMOSET transmission, the display shows
for the four receiver sections, the
Syncing...
button REMOSET button keeps flashing and the
LED status indicators on the transmitters light
up in blue As soon as the four corresponding
transmitters have been set, the button REMOSET
lights continuously again
If the flashing of the button REMOSET slows
down after approx 80 seconds, automatic set-
ting of at least one transmitter has failed or less
than four transmitters are being used To stop the
flashing, press the button EXIT For troubleshoot-
ing see steps 1 – 5 at the beginning of chapter
4 5 5 Check the settings on the corresponding
transmitter and correct them, if necessary Then
press the button REMOSET again
2 For each transmitter separately
It is recommended to make the settings separately
for each transmitter when the settings for a single
transmitter are to be changed or when simulta-
neous synchronization of four transmitters failed
1) Press the button SEL (12) of the corresponding
receiver section On the display, the field of the
receiver section is highlighted
2) Press the button REMOSET; only the settings
of the receiver section selected are transferred
to the corresponding transmitter
in the submenu (see fig 2
Fig. 25