The embedding flange of HUUM CLIFF electric heater is an accessory that you can
request from your HUUM product distributor. A user manual for the embedding flange is
provided with the product.
The maximum permissible immersion of the heater has been provided in Figure 2.
Figure 2. Installing HUUM CLIFF electric heater inside the sauna bench
Connecting the heater to the power supply
NB!
Only a certified electrician is allowed to connect the heater to the
power supply.
• A rubber insulated SIHF-JB cable or an equivalent cable should be used as the
connection cable.
• The maximum current amperage in the cross-sectional area of the cable and
circuit breaker has been provided in Table 1.
• It is recommended to connect the unit to the mains without an earth-leakage
circuit breaker (RCD).
ATTENTION!
It is forbidden to use a non-heat-resistant cable with PVC isolation as
the power cable. When using the junction box in the sauna room, it should be
waterproof and located at a maximum height of 50 cm from the floor.
CLIFF
Mini 4
6
L1 N
1/N~230V
min 550 mm
CLIFF 6
CLIFF 9
L1
CLIFF 11
3/N~400V
1/N~230V
L2
L3
N