ATF will indicate when the procedure is complete (if required by the transmission type - otherwise
this phase will be skipped and the procedure will restart in automatic mode from the converter oil
change procedure).
Asking you to switch off the engine. After switching off the engine, press the «OK» button (if
required by the type of transmission - otherwise this phase will be skipped and the procedure will
restart in automatic mode from the converter oil replacement procedure). Acontainer must be
placed under the sump to collect the used oil (if required by the type of transmission - otherwise
this phase will be skipped and the procedure will restart in automatic mode from the converter oil
replacement procedure). Once the container is in place, press the «OK» button.
Remove the sump, taking care to ensure that a small quantity
of oil remains inside the sump. Remove the sump, taking care
not to spill the contents of the used oil (if required by the type
of transmission - otherwise this phase will be skipped and the
procedure will restart in automatic mode from the converter
oil replacement procedure) and press the «OK» button.
After removing the housing and filter, press the «OK» button.
ATF will refill the radiator by draining the cooling system. The used oil will fall into the oil collection
tray located under the hydraulic power unit.
Once the oil has been changed, replace the filter and gasket (if required by the type of transmission
- otherwise this phase will be skipped and the procedure will restart in automatic mode from the
converter oil replacement procedure).