A variety of optional installation kits are available for
arranging appliances in banks:
G)"Bridge" installation kit
G
ELECTRICAL CONNECTION
Important
The connection must be made by au-
thorised, skilled personnel, in accordance
with the relevant legal requirements, using
appropriate and specified materials.
The appliance is supplied with operating voltage
400V/3N.
IT
Caution - warning
GB
Before doing any work, cut off the mains elec-
tricity supply.
DE
Connect the appliance to the mains electricity sup-
ply as follows.
FR
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
ES
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
English
H)Supporting frame kit
L) Supporting beam kit
H
B
B
A
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Replace the control panel (D) and the knobs (B)
on completion of the operation.
6 - Close the hatch (B).
- 22 -
L
IDM-39614401800.tif
D
C
E
IDM-39614401900.tif
C