ASSEMBLY INSTRUCTIONS
3. Firmly clamp the torque arrestor to the pipe
approximately 2 to 4 ft. above the pump, using
the two clamps provided with the torque arrestor.
(Fig. 3)
4. Typical installations include the following
components. Purchase these items separately
depending on your need.
(Fig. 4)
Discharge pipe - delivers water to home
Well seal or pitless adapter - keeps debris out of
well
Safety rope - prevents pump from falling
Check valve - keeps water in pipe
Electrical cable - connects to house electricity
Torque arrestor - keeps pump stable
Drop pipe - connects pump to discharge
Well casing - holds all components
ELECTRICAL HOOKUP AT THE PUMP
Submersible Cable Splicing
Pump is equipped with a lead wire assembly. The length of wire needed to attach to this lead wire assembly is
equal to the distance from the pump in the well to the top of the well. Additional wire will be needed to run from
the top of the well to the house.
CAUTION: Follow instructions carefully to make a watertight splice. A leak in the splice can result in pump
damage, blown fuses, overload protector tripping or electric shock hazard.
3
4
6
Copyright © 2023 Flint & Walling. All rights reserved.
Torque
Arrestor
Discharge Pipe
Well Seal or Pitless Adapter
Safety Rope
Spring-Loaded Check Valve
(Recommended every 100 ft.)
Electrical Cable (Secured to drop
pipe with tape or clamps every
10 ft.)
Torque Arrestor
Drop Pipe
Well Casing
Pump
Approx. 4 ft.