ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK
2. Remove cover from pressure switch and screw
the switch into the 1/4 in. opening on the top of
the pipe tee. (Fig. 2)
3. Thread the cable from the house electrical service
through one of the holes in the side of the pressure
switch and tighten down the electric wire strain
relief.
CAUTION: Do not crush wire. (Fig. 3)
4. Connect the two wires from the house electrical
service to the outside pressure switch terminals
(L1 and L4). (Fig. 4)
5. Thread the cable from the pump through the
remaining hole in the side of the pressure switch
and tighten down the electric wire strain relief.
CAUTION: Do not crush wire.
2
3
4
5
14
Copyright © 2023 Flint & Walling. All rights reserved.
L1
L4
Strain Relief
L1
L4
IL1162
L1
L4