Télécharger Imprimer la page

Bosch GDR 18V-220 C Professional Notice Originale page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
Do not expose a battery pack or tool to fire or excess-
u
ive temperature. Exposure to fire or temperature above
130 °C may cause explosion.
Follow all charging instructions and do not charge the
u
battery pack or tool outside the temperature range
specified in the instructions. Charging improperly or at
temperatures outside the specified range may damage
the battery and increase the risk of fire.
Service
Have your power tool serviced by a qualified repair
u
person using only identical replacement parts. This
will ensure that the safety of the power tool is maintained.
Never service damaged battery packs. Service of bat-
u
tery packs should only be performed by the manufacturer
or authorized service providers.
Safety Warnings for Impact Wrenches
Hold the power tool by insulated gripping surfaces,
u
when performing an operation where the fastener
may contact hidden wiring. Fasteners contacting a "live"
wire may make exposed metal parts of the power tool
"live" and could give the operator an electric shock.
Use suitable detectors to determine if there are hid-
u
den supply lines or contact the local utility company
for assistance. Contact with electric cables can cause
fire and electric shock. Damaging gas lines can lead to ex-
plosion. Breaking water pipes causes property damage.
Hold the power tool securely. When tightening and
u
loosening screws be prepared for temporarily high torque
reactions.
Secure the workpiece. A workpiece clamped with
u
clamping devices or in a vice is held more secure than by
hand.
Always wait until the power tool has come to a com-
u
plete stop before placing it down. The application tool
can jam and cause you to lose control of the power tool.
In case of damage and improper use of the battery, va-
u
pours may be emitted. The battery can set alight or ex-
plode. Ensure the area is well ventilated and seek medical
attention should you experience any adverse effects. The
vapours may irritate the respiratory system.
Do not open the battery. There is a risk of short-circuit-
u
ing.
The battery can be damaged by pointed objects such
u
as nails or screwdrivers or by force applied externally.
An internal short circuit may occur, causing the battery to
burn, smoke, explode or overheat.
Only use the battery in the manufacturer's products.
u
This is the only way in which you can protect the battery
against dangerous overload.
Protect the battery against heat, e.g. against
continuous intense sunlight, fire, dirt, water
and moisture. There is a risk of explosion and
short-circuiting.
Bosch Power Tools
WARNING
Ensure that the coin cell is kept
out of the reach of children.
Coin cells are dangerous.
Coin cells must never be swallowed or inserted into
u
any other part of the body. If you suspect that
someone has swallowed a coin cell or that a coin cell
has entered the body in another way, seek medical at-
tention immediately. Swallowing coin cells can result in
severe internal burns and death within 2 hours.
Ensure that coin cell replacement is carried out prop-
u
erly. There is a risk of explosion.
Only use the coin cells listed in this operating manual.
u
Do not use any other coin cells or other forms of electrical
power supply.
Do not attempt to recharge the coin cell and do not
u
short circuit the coin cell. The coin cell may leak, ex-
plode, catch fire and cause personal injury.
Remove and dispose of drained coin cell correctly.
u
Drained coin cell may leak and damage the product or
cause personal injury.
Do not overheat the coin cell or throw it into fire. The
u
coin cell may leak, explode, catch fire and cause personal
injury.
Do not damage the coin cell and take the coin cell
u
apart. The coin cell may leak, explode, catch fire and
cause personal injury.
Do not allow damaged coin cells to come into contact
u
with water. Leaking lithium may mix with water to create
hydrogen, which could cause a fire, an explosion, or per-
sonal injury.
Caution! When using the power tool with Bluetooth®, a
u
fault may occur in other devices and systems, aero-
planes and medical devices (e.g. pacemakers, hearing
aids). Also, damage to people and animals in the im-
mediate vicinity cannot be completely excluded. Do
not use the power tool with Bluetooth® in the vicinity
of medical devices, petrol stations, chemical plants,
areas with a potentially explosive atmosphere or in
blasting areas. Do not use the power tool with
Bluetooth® in aircraft. Avoid using the product near
your body for extended periods.
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG, Inc. Any use of such
marks by Robert Bosch Power Tools GmbH is under li-
cense.
Application tools can become hot during operation.
u
There is a risk of burns when changing the application
tool. Use protective gloves to remove the application
tool.
English | 15
1 609 92A 8HZ | (14.12.2023)

Publicité

loading