RS232C SETUP
Here you can change the RS232 settings.
RS232C SETUP
SPEED
LENGTH
STOP B IT
PARITY
SELECT: ▲▼ CHANGE VALUE + -
PANTILT SETUP (PTZ control)
PANTILT SETUP
COMMAND SETUP
SPEED SETUP
SELECT MENU: ▲▼, & [ENTER]
COMMAND SETUP
COMMAND SETUP
CHANNEL
MODEL
PTZ-ID
BAUDRATE
CMD DELAY
COMMAND
LENGTH
CODE
SELECT: ▲▼, CHANGE VALUE : +-
CHANNEL
Use the +/– buttons to select the camera for which you want to change the setup.
MODEL
The digital recorder supports 9 programmed PTZ cameras. Select a camera type with the +/– keys. The
following types are available:
PELCO-D, PELCO-P, ACCUDOME, HMC-250, SCC-641, VIDO AU-GXX, AECD-2000, HID-2404 and
DRX-502A.
PTZ ID
Here you can define up to 255 ID numbers. Give each high-speed motor
PTZ camera its own ID number to distinguish the cameras.
115200
Move the cursor using the direction keys
8
Use the – and + keys to change the values of the selected
1
NONE
menu item.
To exit a menu item, press the menu key (15).
Move the cursor using the direction keys
Confirm your selection with Enter (3) to open another submenu.
To exit a menu item, press the menu key (15).
01
Move the cursor using the direction keys
PELCO-D
Use the – and + keys to change the values of the selected
001
9600 BPS
menu item.
1 MSEC
To exit a menu item, press the menu key (15).
PAN/TILT STOP
07
FF 01 00 00
00 00 01
28
.
▲▼
.
▲▼
.
▲▼