4. Installation Instructions
4.1 TYP 101 90 System E/S
Picture 10
screw
Picture 11
Picture 12
screw
base
Side
extension
Side extension,
superstructure
adjusting
screw
39
TYP 101 90 System E/S fireplace
consists of and can be installed from
individually available elements: a furnace
chamber, base, right/left side extensions,
right/left superstructures.
Fix the furnace chamber to the base with
the use of 2 M8×30 screws (Picture 10).
If the furnace chamber is installed
without a base, only with the right and
left side extensions, fix the furnace
chamber to the side extensions with 2
M8×30 screws (Picture 11).
The connecting screws are provided in
the ashtray.
Stand the right and left superstructures
on
the
side
connection elements.
There are adjustable legs on the bottom
part of the superstructures and side
extensions to set the desired height
(Picture 12).
extensions
without

Publicité