User Manual
Operating Instructions
Monitoring of the Operation, continuation
Fig. 23
Metering device with piston detector
2 -
Piston detector
Fig. 24
Pressure relief valve
Adjusting the Output by Using Metering Screws
Fig. 25
Screwing in of metering screws
3 -
Metering screw
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Operation, continuation
Electrical monitoring (microprocessor control)
A piston detector (initiator, pos. 2) that has been in-
stalled on a metering device instead of a piston closure
plug monitors the pump operating time and brings it to a
close after all the pistons of this metering device have
dispensed their lubricant quantity.
If there is a blockage or the pump reservoir is empty, the
piston detector can no more detect any piston movement.
The switching off signal is not transmitted to the control
unit. A fault signal occurs.
6506b05
The pre-assembled metering devices have the designa-
tion SSV D 6-...-N to 22-...-N (they are available for SSV
D 6, 8, 10, 12 to 22). They must be installed in the system
instead of a normal metering device (SSV D).
Pressure relief valve
The complete system can be visually monitored on the
pressure relief valve of the pump. If lubricant is leaking at
the pressure relief valve during the distribution sequence,
this indicates that there is a blockage in the system.
4092a97
The metering quantities per piston stroke and outlet may
be adjusted by using metering screws of different lengths.
Depending on the length of the metering screw, various
outputs are possible (see page 22, Tab. 2).
6507b05
NOTE
For the system monitoring it is recom-
mended that one SSV D metering device
with pre-assembled piston detector be
used per lubrication circuit. These special
6001a02
metering devices must be ordered sepa-
rately for each lubrication system. Refer to
the Parts Catalog.
IMPORTANT
In the case of the progressive metering
devices models SSV D 6 to SSV D 22 the
outlets 1 and/or 2 must never be closed,
otherwise the system would block owing to
6001a02
the structure of the metering device.
NOTE
Further adaptations of the output result
from an internal cross-porting of outlets
(see page 18 and 19).
6001a02
2.2A-20003-B07
Page 17 of 26