8
Operation
Please note
Premature access to the positioning range of the DNCV−... can cause injuries.
S Make sure that it is not possible to gain access to the positioning range of the
DNCV−... until the piston has come to a complete stand.
If the installation is properly protected, it should not be possible to touch the
DNCV−... until the moveable mass has come to a complete stand.
Changing from lubricated to non−lubricated compressed air.
Please note
If the service life lubrication is washed out, the product will wear to a high
degree.
S Note the reduced service life of the DNCV−... .
9
Care and maintenance
If the DNCV−... is dirty:
Clean the DNCV−... with a soft cloth.
S
Permitted cleaning agents are:
soap suds (max. 60 °C)
all non−abrasive agents.
If there is a reduction in output during continuous operation:
order a wearing parts kit.