Observe ambient temperature
and ventilation
Ambient temperature
The appliance is designed for a specific climate class.
Depending on the climate class, the appliance can be
operated at the following room temperatures.
Climate class
Permitted ambient temperature
SN
+10 °C to 32 °C
N
+16 °C to 32 °C
ST
+16 °C to 38 °C
T
+16 °C to 43 °C
The climate class can be found on the rating plate.
Note
The appliance is fully functional within the room
temperature limits of the indicated climatic class. If
an appliance of climatic class SN is operated
at colder room temperatures, the appliance will not
be damaged up to a temperature of +5 °C.
Ventilation
The air on the rear panel of the appliance heats up.
Conduction of the heated air must not be obstructed.
Otherwise, the refrigeration unit must work harder.
This increases power consumption. Therefore: Never
cover or block the ventilation openings!
E - Nr
FD - Nr
Connecting the appliance
After installing the appliance, wait at least 1 hour until
the appliance is switched on. During transportation
the oil in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
"Cleaning the appliance").
Electrical connection
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with the protection class I.
Connect the appliance to 220–240 V/50 Hz
alternating current via a correctly installed socket with
protective conductor. The socket must be fused with
a 10 to 16 A fuse.
For appliances operated in non-European countries,
check whether the stated voltage and current type
match the values of your mains supply. These
specifications can be found on the rating plate.
m
Warning
Never connect the appliance to electronic energy
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters
are used for photovoltaic systems which
are connected directly to the national grid. Sine-
controlled inverters must be used for isolated
applications (e.g. on ships or in mountain lodges)
which are not connected directly to the national grid.
E - Nr
FD - Nr
21