OPeRATIOn
Recoil Start
NOTE: Read Operator's Manual carefully before operating this
unit. Always make sure the unit is level and properly
grounded. Check engine oil before starting.
. Open fuel valve on unit or engine. (See Fig. 3)
2. Move choke lever to full choke. If re-starting a warm
engine, the choke should be left in the off position. (See
Fig. 4)
3. Turn the engine ignition switch to the ON position.
4. Pull recoil to start engine.
5. Once engine has started, slowly move choke lever to no
choke.
NOTE: When engine fails to start after several attempts, repeat  
the starting procedures mentioned above with the choke  
lever in the off position.
6. Allow the unit to run for two (2) minute warm-up.
7. Make sure the generator is grounded. See Preparing the
Generator; Grounding Instructions.
8. Test the GFCI receptacle(s) on the unit. Push the test button.
The reset button should pop out and there should be no
power at the receptacle. Apply a test load or lamp to each
receptacle to verify. IF THE RESET BUTTON DOES NOT
POP OUT, DO NOT USE THE RECEPTACLES(S). SEE
DEALER FOR SERvICE IMMEDIATELY.
9. If GFCI receptacle(s) test correctly, firmly push the reset
button to restore power. A distinctive click should be
heard or felt when this is complete. IF THE
RECEPTACLE(S) DO NOT RESET PROPERLY, DO
NOT USE THE RECEPTACLE(S). SEE DEALER FOR
SERvICE IMMEDIATELY.
0. Loads can now be applied to the unit.
. If unit is equipped with a Full Power Switch, move the
Full Power Switch to the 20v position to direct all power
to the 20v/30A receptacle on the unit (See Fig. 5). This
will disable all other receptacles.
When the Full Power Switch is in the 20v/240v
position, all receptacles are usable except the 20v/30A
receptacle.
NOTE: This engine is equipped with a "Low Oil" shutdown
system for engine protection. The engine stops when
the oil level gets too low. The engine will not restart
without adding oil. Refer to Preparing the Generator;
Engine Fuel Capacity for instructions on adding oil.
20
Operation
(Fig. 3)
(Subaru Shown)
(Fig. 4)
(Subaru Shown)
(Fig. 5)
(Subaru Shown)
Operator's Manual