The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
The range hood controls are located on the front side of the
canopy. The light switch for the top lights is located on the
underside right of the canopy
A
B
C
D
E
A. Louver holes (non-vented
[recirculating] installations only)
B. Duct covers
C. Bottom light housings
D. Canopy
Control Panel
A
B
A. Power decrease
B. Power increase
C. Display
Display
Grease Filter Saturation Alarm
After 30 hours of fan function, the display will show "Clean
Grease Filter" when the fan is active. When this icon shows in
the display, the installed grease filters should be washed. See
"Range Hood Care" section.
■
To reset the grease filter saturation alarm, press and hold the
Power Increase button for 5 seconds. The "Clean Grease
Filter" icon will no longer be displayed.
RANGE HOOD USE
.
H
G
F
I
E. Grease filters
F. Grease filter handles
G. Light switch - top
H. Top light housings
I. Control panel
C
D
D. Bottom lights
E. Timer
Charcoal Filter Saturation Alarm
After 120 hours of fan function, the display will show "Replace
Charcoal Filter" when the fan is active. When this icon shows in
the display, the charcoal filters should be replaced. See "Range
Hood Care" section.
■
To reset the charcoal filter saturation alarm, press and hold
the Power Decrease button for 5 seconds. The "Replace
Charcoal Filter" icon will no longer be displayed.
Audible Signal Activation and Deactivation
The audible signals can be activated or deactivated by pressing
the Bottom Lights button for 5 seconds.
■
If the audible signal is activated, a tone will sound, and "Snd"
symbol will appear in the display for 3 seconds.
■
If the audible signal is deactivated, the "Snd" symbol will
appear on the display for 3 seconds.
Charcoal Filter (Recirculation Accessory) Inclusion and
Exclusion
When the charcoal filter is in use (recirculating mode), press and
hold the Power Decrease and Power Increase buttons at the
same time for 5 seconds. "Able" will appear in the display for
3 seconds.
If the charcoal filter is not used (vented mode), press and hold the
Power Decrease and Power Increase buttons at the same time
for 5 seconds. "None" will appear in the display for 3 seconds.
E
■
When the charcoal filter has been excluded, the charcoal filter
alarm is disabled.
■
The inclusion or exclusion of the charcoal filter must be
selected while the lights and the fan motor are Off.
Heat Sensor
The control is equipped with a heat sensor that will turn on the
blower to the highest speed if excessive heat occurs around the
control area.
■
If the blower is On or Off, the blower will automatically set to
the highest speed. "Auto" will appear in the display to
indicate that the heat sensor has detected excessive heat.
■
When the blower is operating due to excessive heat detected
by the heat sensor, the blower speed cannot be decreased.
■
When the temperature level on the hood drops to normal, the
blower will return to its setting before the excessive heat was
sensed.