Changing The Floor-Tool Blades - Nacecare Numatic iINTERNATIONAL TTB 2120/100T Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

!
Always ensure that the machine is switched off prior to any maintenance.
To clean the floor-tool, lower the Floor-tool then unscrew the retaining knobs and slide off of the
floor-tool holding bracket.
Rinse the floor-tool assembly with clean water and refit.
53
Periodically the floor-tool blades should be examined and checked for wear and damage.
The blade removal is easy. Simply start by removing the four retaining pins (Fig.52), turn the
floor-tool over and separate the blade carrier from the body (Fig.53-54). Peel away the blades
from their locating lugs (Fig.55) and examine or renew as required.
Replacement is a reversal of the removal process.
1
Floor-tool Main Body
2
Rear Blade
3
Blade Carrier
4
Front Blade (slotted)
5
Retaining Pins x 4
Note: The blades are designed to be reversible, thus extending their useful working life.

Changing the Floor-tool Blades

52
54
4
3
2
1
17
55
5
!

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Numatic iinternational ttb 2120/120t

Table des Matières