2.3 DRAINING OFF THE WATER
• The water which condenses on the evaporator bla-
des is collected in a tank . It is therefore necessary for
the dehumidifier to be placed on a flat and level and
raised surface which allows the water to drain off and
which prevents the water in the tank from running
over . The dehumidifiers from Trotec are equipped with
the following connecting points to drain off the con-
densed water .
Model DH150:
22 mm connecting pipe
Model DH300:
G ¾-inch pipe thread connector
Model DH600:
G 1½-inch pipe thread connector

2.4 ELECTRICAL INSTALLATION

(CABLING AND POWER SUPPLY)
• The electrical installation must fulfil the require-
ments of the most current existing local guidelines .
• The power supply must be protected by fuses and a
circuit breaker for the motor (see technical data
sheet) . A cut-off switch must also be installed next
to the unit .
• All machines and appliances must be properly
grounded . We recommend installing a residual
current operated protective device (RCD) .

• IMPORTANT:

The performance values can only be achieved if the
following voltage and frequency limits are observed:
Units with a single phase: Nominal voltage 230 V,
± 10 % Units with three phases: Nominal voltage 400 V
± 10 % Frequency nominal frequency 50 Hz: ± 5 %
IMPORTANT: These voltages must be given when the
dehumidifier is operated at full power .
please nOte: All the units are equipped with a pha-
se failure relay . If a phase is missing or a there is no
clockwise rotating field, the relay control lamp is off
and the drier will not run .
B - 3
03. cOntrOl eleMents anD InDIcatOr laMps
External Operating Console:
• POWER SUPPLY – RED:
Lights up when the power supply of the dehumidifier
is switched ON .
• FAULT – YELLOW:
Lights up when there is a fault at the internal safety
switch or when the locking chain is open .
• DEFROST – WHITE:
Lights up when the dehumidifier is switched to
Defrost mode . This occurs automatically at low
temperatures and is NOT a fault! The dehumidifier
switches back automatically to normal mode when
the defrosting cycle is completed .
• ON/OFF switch:
Only for the DH150 . This switch should only be used
when you are not planning on using your dehumidifier
over a longer period or when you wish to disconnect
it from the main power supply .

• STANDBY SWITCH:

Only for the DH300/600 . This switch should only be
used when you are not planning on using your
dehumidifier over a longer period or when you wish
to disconnect it from the main power supply .
m
ted from the power supply for longer than an hour,
the stanDY swItch has to be switched to stand-
by. the dehumidifier must remain in standby for
12 hours before you can switch to normal mode.
Internal control elements:
• The adjustable internal relative humidity control
(range 20/80 %) should be set to 60 % to achieve
a pleasant room climate in the home or office while
producing as little condensed water as possible .
(At 20 % more moisture is drawn out of the ambient
air than at 80 %) .
• The adjustable temperature control should be set to
the highest temperature you wish to have in the
area you wish to dehumidify .
Operating manual – DH 150 / 300 / 600
when the unit is switched on for the first
time, or when the unit has been disconnec-
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dh 3000Dh 600Dh w 150axDh w 150bxDh w 300byDh w 600by

Table des Matières