Télécharger Imprimer la page

Keysight Technologies E36200 Serie Mode D'emploi page 101

Publicité

Les langues disponibles

Les langues disponibles

Data logger properties and waveform settings
Items
Available settings
1
Vertical Settings
Trace checkbox
(Vr)
2
Horizontal Set-
Time/Division
tings (Hr)
Offset
3
Logging (Lg)
Duration
Sample Period
Trigger Source
Trigger Pos
Log Min/Max checkbox When enabled, lets you log the minimum and maximum values of each sample to the data
Menu
Available settings
File Selection
-
Preset
Settings
Vr, Hr or Lg
Keysight E36200 Series User's Guide
Selects the trace to display for the output. If no checkbox is enabled, data logging will not
logged for the selected output.
Configures the voltage/division, current/division, power/division and offsets for each out-
put.
Configures to zoom in or out of the data so that you can view waveform details. The
numbers on the top of the display indicate the location of the data that is being viewed
relative to the entire data log. Specified in time/division on the x axis. Applies to ALL
traces.
Configures the waveform location (right or left) of the horizontal offset reference. The trig-
ger point is indicated by the solid arrow .
Configures the duration of the data log in hours, minutes, and seconds. The maximum
duration is 30,000 hours. The logging information applies to data logger measurements
on all outputs.
Configures the interval between data samples in milliseconds, which can be set from 200
milliseconds to 60 seconds.
Configures the trigger source for data logger.
Trigger Position specifies a trigger offset. This allows the specified time of pre-trigger
data to be logged to the file. For example, if you specified a data log duration of 30 s and a
trigger position of 50%, the Data Logger will log 15 s of pre-trigger data to the file before
the trigger occurs. Subsequently, 15 s of post-trigger data will then be logged to the data
file.
log file. With Log Min/Max checked, the resulting file size will triple.
Configures the file location and filename for logged data, export the file to .csv format and
load the previously logged file to the instrument.
Returns the Data Logger View to the power-on display settings.
Selects the Vertical Settings, Horizontal Settings or Logging Settings field.
Action required:
Press Settings to toggle between Vr, Hr and Lg.
Description