Wiring must comply with applicable electrical standards and include
a properly sized fuse or circuit breaker. Improper wiring can cause a
fire resulting in injury or death.
CAUTION: Suggested wiring information is given as a reference. For proper
information, please reference ABYC E-11, AC and DC Electrical Systems on
Boats guidelines.
Wire Size Table
Total Wire Length - feet (meters)
Pump
Voltage
12 VDC
24 VDC
CAUTION: Motor case could get hot during extended operation. Prolonged contact with skin
may cause a burn.
WARNING: Electrical connections should be performed by a competent marine electrical technician.
CAUTION: Disconnect power from the system before working on the unit to avoid personal
injury, damage to the surrounding environment and/or damage to the unit.
Electrical Installation
Diagram
Operation
Figure 6.
Important: Do not operate the pump more than 15 minutes continuously.
WARNING
FI R E HAZ A RD
0 - 20 ft
(0 - 6 m)
#14 AWG
(2.5 mm
)
2
#16 AWG
(1.5 mm
)
2
Figure 5.
Initial Start Up
Demand Off
Demand On
20 - 35 ft
(6 - 9 m)
#12 AWG
(4 mm
)
2
#14 AWG
(2.5 mm
)
2
• Fill water tank
• Open all faucets
• Turn pump switch "ON"
NOTE: Expect a 10 second delay
for power up.
• When water is free of air, turn
all faucets off beginning with
the faucet closest to the pump
(Figure 6)
35 - 55 ft
(9 - 12 m)
#10 AWG
(6 mm
)
2
#12 AWG
(4 mm)
5