2. INSTALLATION INSTRUCTIONS
 
Remove the  external  packaging, remove the  protective plastic film from the surface of the appliance 
and clean the external parts of the appliance with a cleaner designed for this purpose. Do not use steel 
wool or any coarse agents, which could irreparably damage the surface of the appliance.  
IMPORTANT
This  unit  can  be  installed  as  either  built‐in  or  free‐standing  unit.  For  built‐in  installation,  certain 
clearances are necessary for optimal operation. In this case, allow 3/16" on both sides, 2" at the rear 
and  1/16"  at  the  top  to  ensure  proper  ventilation.  Take  care  that  the  air  vent  at  the  front  of  the 
appliance is never covered or blocked in any way. 
 
BEFORE INSTALLATING OF YOUR APPLIANCE 
 
The placement of the appliance must meet the requirements in the section operating conditions 
and must include a stable floor with a load‐bearing capacity corresponding to the weight of the 
appliance. 
Level the appliance using the adjustable feet. Ensure there is a gap between the bottom edge of 
the  appliance  and  the  ground,  so  that  there  is  sufficient  circulation  of  air.  This  will  ensure  the 
optimal performance of the cooling system. 
Use the appliance only for the purposes for which it has been designed. 
The  appliance  must  be  located  on  a  rigid  and  even  surface.  In  this  way  you  will  ensure  free 
circulation of the coolant and effective operation of your appliance. 
Place the appliance in a cool, well ventilated and dry room. 
Do not locate the appliance in direct sunlight or in a room with a high ambient temperature, or 
in  the  vicinity  of  any  sources  of  direct  heat,  such  as  a  radiator  or  oven.  This  would  cause  the 
compressor to work harder, resulting in a substantially higher power consumption level. 
ELECTRICAL REQUIREMENTS 
A 115 Volt / 60 Hz grounded electrical supply equipped with a 15 or 20 amp fuse or circuit breaker is 
required. It is recommended that a separate circuit serving only your appliance be provided. Use outlets 
that cannot be turned off by a switch or pull chain. Connect this appliance to a 3‐prong power supply 
outlet  that  has  a  ground  terminal.  If  you  only  have  a  2‐prong  outlet,  have  it  replaced  by  a  qualified 
technician  with  an  outlet  that  meets  the  local  codes.  DO  NOT  USE  AN  EXTENSION  CORD.  Required 
nominal voltage and frequency are indicated on  the rating plate. The connection  to the  power supply 
and grounding has to be made according to current local standards and regulations. 
 
BUILT‐IN INSTALLATION DIMENSIONS (MM/IN) 
If your appliance is to be built‐in, follow the diagram and chart below for appropriate dimensions. 
 
 
 
Chart 
610mm (24")   
610mm (24")   
883mm (34 ¾")  
152mm (6") 
51mm (2") 
20
 
 

Publicité

loading

Ce manuel est également adapté pour: