Mounting
Injectors can be mounted in any position
and can be used in circuits with SL-42,
SL-43, SL-44 injectors.
Specifications
Maximum operating pressure
Normal operating pressure
Maximum vent (recharge) pressure
Lubricant output is adjustable from
Adjusting
procedure
1 Turn the adjusting screw (1) all the way in
until it stops.
2 Back the adjusting screw (1) out 9 turns
from this position which will give you the
approximate minimum lubricant output.
3 Each turn out from that minimum position
will increase the output by approximately
0.008 in
3
(0.131 cm
3
) of lubricant.
4 Maximum lubricant output of
approximately 0.080 in
3
achieved at approximately 16 turns from
the totally closed position.
5 Lubricant output accuracy should be
verified for critical bearing requirements.
1 000 psi (69 bar)
850 psi (59 bar)
150 psi (10 bar)
0.008 to 0.08 in
3
(0.131 to 1.31 cm
6
(1.31 cm
3)
is
3
)