Starting the Generator (Recoil Start)
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level and fuel.
3. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned on.
4. Turn the fuel valve to the "ON"(l) position.
5. Pull the choke lever out to the "CHOKE" position.
English
6. Flip the engine switch to the "RUN"(l) position.
7. Pull the starter cord slowly until resistance is
felt and then pull rapidly.
8. Push the choke button to the "RUN" position.
9. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
WARNING
S t a r t e r c o r d k i c k b a c k ( r a p i d
retraction) will pull hand and arm
toward engine faster than you can
let go which could cause broken
bones, fractures, bruises, or sprains resulting in
serious injury.
When starting engine, pull cord slowly until
resistance is felt and then pull rapidly to avoid
kickback.
Page 15