Avoid taking the load in areas where it could be a danger if dropped.
- During transport and storage, avoid exposure to rain or persistent humidity.
- The boiler must only be moved in a vertical position by forklift, resting on the base.
- Use suitable equipment to remove the boards or wooden parts of the boiler packing.
- Disposal or recycling of the packing must be done by the end user, complying with local regulations on
waste and keeping it out of the reach of children or disabled persons.
2.2 Place of installation, positioning and fire-prevention safety
After preparing the water and electrical connections (by a qualified technician), open the packing and remove the
boiler from pallet.
After removing the protective packing, be careful not to damage the mechanical and electrical parts by knocking or
splashing with water.
Place the boiler in the required location, making sure it:
- complies with the requirements of the regulations in force,
- complies with correct operation of the unit,
- is possible to operate and service the unit in any position needed to do the work,
- is provided with adequate ventilation from the outside,
- is provided with a suitable fume exhaust system,
- is provided with an approved, grounded power socket.
Set the boiler down on the floor very carefully without any bumping and position it in the required place. Make sure
the floor can take its weight, otherwise see a specialized technician.
After positioning the boiler, fit the 4 feet (included the bag supplied) which stabilize the unit if the floor is not perfectly
flat: to fit and/or adjust the height of each foot, tilt the boiler where and as necessary.
The unit is suitable for operation in technical environments with min. temperature not below 0°C; it comes complete
with an antifreeze function that activates the heating pump for system water temperatures below 6°C, safeguarding:
heating chamber, heating/DHW circuit. The antifreeze function is active only when the boiler is electrically powered.
The boiler must also be suitably separated from flammable or combustible materials by air spaces or the use of
appropriate protective insulation; floors and/or ceiling-coverings in flammable or heat sensitive material must be
protected by panels of insulating material.
Make sure there are spaces at the sides and rear of the boiler, necessary for servicing and cleaning the unit, fume
ducts and the flue.
Also make sure the pellet hopper is easily accessible for loading the fuel.
The minimum distances for maintenance and safety must comply with the following table:
44
Positioning feet
NATURFIRE 17-25 HR