Télécharger Imprimer la page

Bosch GWS 12-125 S Professional Notice Originale page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
12 | English
Flap disc
Always fit the hand guard (21) when working with the
u
flap disc.
Rubber sanding pad
Always fit the hand guard (21) when working with the
u
rubber sanding pad (23).
See the graphics page for fitting instructions.
Screw on the round nut (25) and tighten with the two-pin
spanner.
Cup brush
Always fit the hand guard (21) when working with the
cup brush.
See the graphics page for fitting instructions.
The cup brush must be screwed onto the grinding spindle
until it rests firmly against the grinding spindle flange at the
end of the grinding spindle thread. Tighten the cup brush
with an open-ended spanner.
Quick-clamping nut
To change the abrasive tool easily without having to use any
additional tools, you can use the quick-clamping nut (13) in-
stead of the clamping nut (14).
The quick-clamping nut (13) may be used only for
u
grinding or cutting discs.
Only use quick-clamping nuts (13) that are in good work-
ing order and not damaged.
When screwing on, make sure that the printed side of the
quick-clamping nut (13) is not facing the grinding disc;
the arrow must be pointing towards the index mark (28).
(28)
1 609 92A 72X | (23.06.2022)
Press the spindle lock but-
ton (2) to lock the grinding
spindle. To tighten the
quick-clamping nut, turn
the grinding disc firmly
clockwise.
If the quick-clamping nut
has been attached correctly
and is not damaged, you
can loosen it by hand by
turning the knurled ring an-
ticlockwise. If the quick-
clamping nut is stuck, do
not attempt to loosen it
with pliers – always use
the two-pin spanner. Posi-
tion the two‑pin spanner as
shown in the figure.
Approved abrasive tools
You can use all the abrasive tools mentioned in these operat-
ing instructions.
-1
The permissible speed [min
] or the circumferential speed
[m/s] of the abrasive tools used must at least match the val-
ues given in the table.
It is therefore important to observe the permissible rota-
tional/circumferential speed on the label of the abrasive
tool.
Max. [mm]
D
b
125
7
150
7
125
75
30
82
Rotating the Machine Head (see figure A)
Pull the plug out of the socket before carrying out any
u
work on the power tool.
The machine head can be rotated in 90° increments. In this
way, the on/off switch can be brought into a more favourable
handling position for particular applications, e.g. for left-
handed tool users.
Completely unscrew the four screws. Rotate the machine
head carefully, without removing it from the housing, into
the new position. Screw in and retighten the four screws.
Dust/Chip Extraction
The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
– Provide good ventilation at the workplace.
– It is advisable to wear a P2 filter class breathing mask.
The regulations on the material being machined that apply in
the country of use must be observed.
[mm]
-1
d
[min
]
[m/s]
22.2
11,000
80
22.2
10,000
80
11,000
80
M 14
11,000
45
M 14
11,000
80
Bosch Power Tools

Publicité

loading

Ce manuel est également adapté pour:

Gws 12-150 s professional