6. Alarms
Two types of alarm may appear on the remote control
Alarm type 1
• Steady green LED and flashing red LED on the electronic board.
• An alarm message appears on the wireless remote control and the
button flashes.
OK
• The conditioner continues to operate.
Once the problem has resolved, press the synchronisation key of the appliance or the
Alarm message
AS2c
A SL
A SH
AHRH
A SO
AS3c
AS3H
AS3O
AVEc
AVCc
ArF
10
Source of error
T° sensor + cellar humidity
Condenser T° sensor
Evaporator fan
Condenser fan
Loss rF (Radio Frequency)
Alarm type 2
• The red LED on the electronic board flashes.
• An alarm message appears on the wireless remote control
and the
OK
• The conditioner is no longer operating.
• Contact your EuroCave stockist.
key to restart.
OK
Description
Cellar ambient temperature sensor loss of power
Cellar temperature level low
Cellar temperature level high
Cellar humidity level high
Cellar temperature fault
Condenser temperature sensor loss of power
Condenser temperature level high
Condenser temperature fault
Evaporator fan fault
Condenser fan fault
Loss of radio frequency communication
button flashes when a key is pressed.
Type of error
type 2
type 1
type 1
type 1
type 1
type 1
type 1
type 2
type 2
type 2
type 1