4. Scope of delivery
Effect on the mortise lock
The SmartHandle AX acts exclusively on the latch of
the mortise lock.
Locking and insurances
Insurance companies place increased demands on a
closure.
1. If you want to lock the door under insurance law,
use a self-locking panic lock or a locking cylinder in
addition to the SmartHandle AX.
2. Pay attention to the approvals according to EN 179.
SmartHandle AX with self-locking panic lock
The SmartHandle AX only offers full functionality with
a self-locking panic lock.
1. Combine the SmartHandle AX with a self-locking
panic lock.
2. Pay attention to the declarations of conformity of
the lock manufacturers according to EN 179.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad
excludes authorisation security class D according to
DIN EN 16867:2020.
Panic bar manufacturer's documentation
Also observe the panic bar manufacturer's document-
www.cisa.com
ation (
or
Pre-bent adapter plate
The adapter plate for the fitting is pre-bent. Its pre-
tensioning ensures a frictional connection with the
door after installation.
Spare screw included
A spare screw is included in the delivery.
Use this spare screw if you have lost a screw to fit
the adapter plate.
4. Scope of delivery
SmartHandle AX (Panic bar version for CISA or
BKS)
Special tool
Quick guide
Blank cylinder
5. CISA design
1
6. BKS design
2
56 / 104
www.g-u.com
).
7. Preparing the door for CISA
(drilling template)
Pin or scriber at hand.
ü
ü
Drill at hand.
ü
Suitable drill bits at hand (Ø6.5 mm and 8.0 mm).
ü
PH2 screwdriver at hand.
ü
Countersink at hand.
1. Insert the spindle into the mortise lock.
3
2. Place the drilling template on the spindle.
4
3. Align the drill template vertically using the printed
scale.
4. Mark the points to be drilled on the door.
5
5. Remove the drilling template.
6
6. Remove the spindle.
7
7. Remove the mortise lock (PH2).
8
8. Drill the required holes.
9
9. Countersink the lowest hole with a countersink.
10
10. Fit the mortise lock (PH2).
11
8. Preparing the door for BKS
(drilling template)
Pin or scriber at hand.
ü
PH2 screwdriver at hand.
ü
Ruler at hand.
ü
Drill at hand.
ü
Suitable drill bits at hand (Ø6.5 mm and 8.0 mm).
ü
1. Remove the mortise lock (PH2).
12
2. Measure the vertical distance between the centres
of the fixing holes.
13
3. Fit the mortise lock (PH2).
14
Digital SmartHandle AX Panic bar