CONVERSION INSTRUCTION
Final assembly
Start up
When the appliance is not connected to the gas supply , check the
gas tightness with a pressure pump:
1. Connect the pressure pump to the gas pipe and close all gas taps.
2. Increase the pressure to 150 mbar and close the tap between
the pressure pump and the pressure gauge. Check the pressure.
The maximum pressure drop is allowed up to 5 mbar per minute.
After checking, open the tap between the pressure pump and the
pressure gauge. Open one of the taps and close the corresponding
injector.
Attention; press and open a tap with thermo electric safety device and
keep it pressed down.
3. Increase the pressure to 150 mbar and again close the tap between
the pressure pump and the pressure gauge. Check the pressure.
The maximum pressure loss may amount to 5 mbar per minute.
4. Repeat for every burner.
1. Replace gaskets on top of the burners.
2. Place the drip tray on the appliance starting with the front side.
The hooks on the front of the drip tray must be placed under the
edge of the under tray. For enamelled drip trays, do not forget to
connect the earth cable to the drip tray.
3. Install the screws around the burner to secure the drip tray.
For enamelled drip trays, use new fiber rings under the screws.
4. Tighten the screws of the brackets at the underside of the appliance.
1. Install the knobs, the burner parts and pan supports.
2. Check whether the appliance is connected to the correct type of
gas and gas pressure.
3. Open the main gas valve and insert the plug into the power socket.
EN 7