Télécharger Imprimer la page

Westinghouse WGen5300c Mode D'emploi page 18

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
MAINTENANCE
Fire hazard. DO NOT up-end the generator or place it on
its side. Fuel or oil can leak and damage to the generator
may occur.
Accidental start-up. Disconnect the spark plug boot from
the spark plug when performing maintenance on the
generator.
MAINTENANCE SCHEDULE
Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil
Clean air filter
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Fuel valve maintenance
Inspect/adjust valve clearance
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Change oil every month when operating under heavy
1
load or in high temperatures.
Clean more often under dirty or dusty conditions.
2
Replace air filter if it cannot be adequately cleaned.
Recommend service to be performed by authorized
3
Westinghouse service dealer.
MAINTENANCE REMINDERS
Maintenance reminder codes will be shown on the Data
Display based on unit Lifetime Hours. The maintenance
codes will be displayed until the unit is turned off. Refer to
the Maintenance section for specific procedures.
18 | Westinghouse Outdoor Power Equipment, LLC
1
2
3
Maintenance Code Required Maintenance
P25
Change engine oil
P50
P100
MAINTENANCE REPLACEMENT PARTS
Description
Air filter
Oil drain plug crush washer
Spark arrestor
Spark plug
AIR FILTER MAINTENANCE
The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Release the clips and remove the air filter cover.
3. Clean the air filter with compressed air. Replace if
damaged.
4. Make sure the air filter and rubber cap are correctly
installed. Install the air filter cover and secure it in place
with the cover clips.
• Change engine oil
• Clean air filter
• Change engine oil
• Clean air filter
• Fuel valve maintenance
• Inspect/adjust valve clearance
Part Number
5941
94007
6790
97108 (F7TC)

Publicité

loading