Symbol
Signal
A buzzer
sounds and the
red light comes
on.
The red light
flashes.
The red light
flashes and the
warning trian-
gle comes on.
The red light
comes on.
The yellow light
comes on.
The red light
comes on.
To move the product
Make sure to use a closed vehicle during transportation
of the product.
Make sure that the intake valve is closed. Make sure
that the dust caps are on the hoses.
1. Make sure that the Longopac is installed on the
product.
2. Make sure that the Longopac bag is empty.
2002 - 003 - 30.06.2023
Cause
The prefilter is clogged.
The incorrect hose is attached or
selected in the control panel.
The hose is damaged or com-
pressed.
The hose is clogged.
The main vacuum hose is dis-
connected.
The HEPA filters are missing, full
or damaged.
The control unit is damaged.
The ambient temperature is too
high.
Warning.
The HEPA filters are almost full.
The HEPA filters are full.
Transportation, storage and disposal
Solution
Do a filter purge procedure. Refer to
filter purge procedure on page 12 .
Attach the correct hose or select the correct
hose dimension on control panel.
Replace the hose.
Clean the hose and remove the blockage.
Let an approved service agent repair the
product.
Do a check of the HEPA filters, replace the
HEPA filters if it is necessary. Refer to
replace the HEPA filter on page 17 .
Let an approved service agent repair the
product.
Make sure that the ambient temperature is in
specified range when you use the product.
Look at the operation record of your Husq-
™
varna Fleet Services
app or speak to an
approved service agent.
Replace the HEPA filters if it is necessary.
To replace the HEPA filter on page
Refer to
17 .
Replace the HEPA filters. Refer to
place the HEPA filter on page 17 .
To do a
To
To re-
21