Télécharger Imprimer la page

Chauvet Professional Legend 330SR Spot Manuel De Référence page 3

Publicité

Les langues disponibles

Les langues disponibles

EN
Lamp
Replacement
1.
Turn the product off and disconnect it from power.
2.
Wait at least 15 minutes for the lamp to cool down.
3.
Remove back cover using the 2 Phillips-head ¼-turn screws.
4.
Take note as to the orientation of the lamp. Vent holes on the front of
the lamp should align horizontally with the air vents on the lamp
frame. Orient the rear of the product so that the fan is facing
downward.
5.
Using the lamp base, push the lamp down against the spring clips
located on the bottom, and then roll the lamp out the top.
6.
Remove the 2 wires connected to the lamp by the spade connectors.
7.
Reverse steps 3 thru 6 above to install the new lamp.
Please refer to the User Manual for more detailed instructions with images.
Lamp
Lamp Vent
RISK OF LAMP EXPLOSION! Vent holes on the front of the lamp should
align horizontally with the air vents on the lamp frame. This is extremely
important for lamp cooling.
Legend™ 330SR Spot QRG
3
¼-turn
Phillips-head
Screws
Spade
Connectors
Spring
Clips