EN
Problem
Appliance not working;
no symbols light up.
I cannot read the LC
display because it is in
the wrong language.
Machine brews but no
drink dispensed.
Automatic mode
O
not working, appliance
remains in stand-by
mode.
Automatic mode
O
skipped, appliance
goes straight to
manual mode.
N
Brewing unit cannot be
securely closed.
More Customer Service information is available online at www.tassimo.com
All manuals and user guides at all-guides.com
Possible cause
There is no power supply.
You may want to change the
language setting.
The water tank was removed
during the brewing process or
there is air in the system.
The float in the water tank is
stuck.
No T DISC inserted.
The barcode could not be
detected.
The barcode could not be
detected.
Piercing unit / T DISC holder
is not properly inserted.
The T DISC is not inserted
properly.
The brewing unit is not
properly closed.
Solution
Check that the appliance is
properly plugged into the
power supply.
Please proceed as described
in the section "Controls and
displays".
Replace the water tank in the
appropriate position in your
TASSIMO machine. Start a
cleaning process with the
Service disc.
Clean the water tank and
ensure the float can move.
Check if T DISC has been
inserted.
Clean the bar code reading
window and try again or
smooth the barcode on the
T DISC out with your thumb.
Use another T DISC.
If problems persist contact
TASSIMO or Bosch Customer
Service Department at 1-877-
TDISCS1 (1-877-834-7271).
Clean the bar code reading
window.
Use another T DISC.
You can still prepare the drink
by holding down the start /stop
button.
Insert the T DISC holder and
piercing unit properly.
Re-insert the T DISC and
make sure it is properly
positioned.
Push the clamp down firmly
until it audibly clicks into
place.
17