Replacing A Fuse; How To Store The Heater - Shizuoka Seiki Co. VAL6 MPX Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

■ Replacing a nozzle
Unscrew two screws of the burner cover
1
and take the burner cover off.
Disconnect the red wire of overheat protec-
2
tion at the back of the burner base.
Unscrew three nuts and pull out the burner
3
unit.
Replace with a new nozzle by using the
4
provided nozzle wrench.
Nozzle Wrench
Tighten the nozzle using the nozzle wrench
5
until the nozzle is fixed.
Observations
• Be careful not to touch electrodes

How to store the heater

6
CAUTION
When you store the heater, please disconnect the power plug from the extension cord and/or the
AC outlet and store the heater indoors where it is less humid.
• Do not store the fuel over summer months for use during next heater season. Using old fuel could damage the heater.
14
Nozzle
• If the heater is stored or not used for an extended period of time, empty the fuel tank to
help prevent fuel leakage and other possible fire dangers.
Observations
Put the burner unit back with three nuts re-
6
moved.
Put the red wire back.
7
Put the burner cover back with two screws
8
removed.

■ Replacing a fuse

Unscrew two screws of burner cover and re-
1
move the burner cover.
Unscrew the screw cap of fuse holder and
2
take out the fuse.
Replace with a new one.
3
Put the screw cap back into fuse holder.
4
Put the burner cover back with two screws
5
removed.
Fuse
Open a screw cap and
take out a fuse.
Check whether the fuse
is blown out.

Publicité

Table des Matières
loading

Table des Matières