Periodic Inspection; How To Replace The Nozzle & Fuse - Shizuoka Seiki Co. VAL6 MPX Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

■ Inspection and cleaning of the flame monitor
• When removing the flame monitor, hold it by its main assembly; do not pull out the cord.
Remove the burner cover and pull out the
1
flame monitor, and check whether or not its
lens is dirty/foul.
If the lens is dirty/foul, clean the surface of
2
the lens with a soft cotton swab or cloth until
it is clear. Do not use any cleansers of any
type, e. g., glass cleaner, to clean the lens.
Replace the flame monitor. Then securely
3
replace the burner cover using the provided
screws.
■ Inspection of "dirt/dust" on the main unit
Check whether or not dirt/dust is on and
1
around the heater.

4-2. Periodic inspection

The heater must be checked periodically, and especially after periods of sustained or heavy use,
for safe and proper operation, and for service maintenance. Have your dealer inspect the heater no
less than twice a year.
How to replace the Nozzle & Fuse
5
WARNING
CAUTION
Observations
• Never service the heater while it is burning, in operation, hot or plugged-in to avoid
any injury and/ or trouble.
• Before starting any service to avoid electric shock, please make sure the heater is shut
down and that the power cord is disconnected.
• When servicing the heater, please wear gloves to prevent possible injury.
Pull out
Lens
Cotton Swab
If dirt or dust is found, remove it with a vacu-
2
um cleaner or a soft, non-abrasive, cloth. Do
not use any cleansers of any type, especially
spray cleansers, as they may leave a resi-
due or infiltrate the operating mechanism of
the heater and cause a fire or clog or other-
wise damage the heater.
Flame Monitor
Flame Monitor
Soft Cloth
13