ENGLISH
Module location (fig. 9a, 9b, 9c)
ICF with two modules
Function Module Type
ICFE/ICFA
Solenoid valve module
ICFE20H
Solenoid valve module
ICFO
Manual opening module
ICFB
Blank top cover
ICFW
Welding module
ICFC
Check valve module
ICFC 20P1
Check valve module
ICFN 20
Stop & check valve module
ICFR
Manual regulating valve module
ICM
Motor valve module
ICFD 20
Defrost module
ICFS
Shut-o valve module
ICFF
Strainer module
ICM
Motor operated valve module
*) Not in combination with ICFO
ICF with four modules
Function Module Type
ICFS/ICFS SS
Stop valve module
ICFR/ICFR SS
Manual regulating valve module
ICFF/ICFF SS
Filter (strainer) module
ICFE/ICFE SS
Solenoid valve module
ICFC/ICFC SS
Check valve module
ICFN / ICFN SS
Stop/check valve module
ICM/ICM SS
Motor valve module
ICFB/ICFB SS
Blank top cover
ICFA/ICFA SS
Electronic expansion valve module (not for ICF 25)
ICFE 20H/ICFE SS 20H
Solenoid valve module (not for ICF 25)
ICFO/ICFO SS
Manual opening module (not for ICF 25)
ICFW/ICFW SS
Welding module
ICFD
Defrost module
ICFG
Pilot-operated servo module
ICF with six modules
Function Module Type
ICFS/ICFS SS
Stop valve module
ICFR/ICFR SS
Manual regulating valve module
ICFF/ICFF SS
Filter (strainer) module
ICFE/ICFE SS
Solenoid valve module
ICFC/ICFC SS
Check valve module
ICFN / ICFN SS
Stop/check valve module
ICM/ICM SS
Motor valve module
ICFB/ICFB SS
Blank top cover
ICFA/ICFA SS
Electronic expansion valve module (not for ICF 25)
ICFE 20H/ICFE SS 20H
Solenoid valve module (not for ICF 25)
ICFO/ICFO SS
Manual opening module (not for ICF 25)
ICFW/ICFW SS
Welding module
ICFD
Defrost module
ICFG
Pilot-operated servo module
Module locations are indicated by M1, M2, M3, M4, M5 and M6. With respect to refrigerant ow, M1 is closest to inlet.
location not possible
*) ICF 15 - M1 and M2 modules are xed (stop valve and lter, respectively)
Use only original Danfoss parts, including O-rings and gaskets for replacement.
Materials of new parts are certified for the relevant refrigerant.
In cases of doubt, please contact Danfoss.
© Danfoss | Climate solutions | 2022.06
Can be installed in these locations
M1
M1*
M2
M1
M2
M1
M2
M2
M2
M2
M1
M2
M1
M2
M1
M2
M2
M1
Can be installed in these locations
M1
M2
M3
*)
M1
M2
M3
M2
*)
M3
M1
M3
M1
M2
M3
M1
M3
M1
M3
M1
M2
M3
M2
M3
Can be installed in these locations
M1
M2
M3
M1
M2
M3
M2
M3
M1
M3
M1
M2
M3
M1
M3
M1
M3
M1
M2
M3
M2
M3
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M5
M6
M4
M5
M6
M4
M6
M4
M6
M4
M6
M5
M4
M5
M6
M5
M5
M4
M4
M5
M6
M4
M6
AN13978644420802-001501 | 7