Application Programs

9.9 Dosing

The following dosing functions can be set:
f
f
f
f
f
Select the dosing function in setting mode (see separate description
470.702.119 User Mode and 470.051.109 Dosing).
Setting the switching points
Use the switching points (see Chapter 9.6) to set coarse flow, fine flow and cor-
rection value.
Switching
point
S1
S2
S3
S4
The greatest possible switching point is the maximum scale load.
Dosing operation
Tare the container as required.
Note: A dosing start interlock with an untared scale must be selected in setting
mode (see separate description 470.702.119 User Mode).
Start the dosing function by pressing the Function key.
The dosing valve opens and the dosing product starts flowing.
The yellow LED lights up and the display flashes until the set dosing weight is
reached.
The green LED lights up when the dosing weight is reached and is within the
tolerance. The dosing valve closes.
The red LED lights up when the upper dosing weight tolerance is exceeded.
Coarse and fine dosing without correction value
f
Coarse and fine dosing with correction value
f
Coarse dosing without and fine dosing with correction value
f
Fine dosing without correction value
f
Fine dosing with correction value
f
Parameter
Setpoint for coarse dosing
Setpoint for fine dosing
Correction value for coarse dosing
Correction value for fine dosing
9
51