Changing The Hepa Filter (Accessory); Maintenance; Recycling - ESAB Origo Vac Cart Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
© ESAB AB 2011
7

Changing the HEPA filter (accessory)

If the unit has been supplied with a HEPA filter, the filter is to be changed when the
main filter cartridge is changed.
WARNING!
Risk of personal injury.
Use necessary personal safety equipment when changing the HEPA filter.
Change the HEPA filter cartridge as follows (see also Figure 6):
1.
Disconnect the mains connection cable.
2.
Unscrew the top cover.
3.
Remove the used HEPA filter and put it in the plastic bag which comes with the
new HEPA filter. Close the plastic bag.
4.
Handle the used HEPA filter according to the relevant regulations for the
substances that have been collected.
5.
Check that the new HEPA filter not is damaged. Note that the filter surface must
not be touched. Handle the HEPA filter very carefully and fit it in the unit. Ensure it
is fitted in the correct position and that the seal is downwards. Check that the seal
not is damaged. Note the UP-arrows.
6.
Refit the top cover. Fasten it securaly.
8

Maintenance

Maintenance is recommended at least once a year. Repair and electrical work is to be
performed by an authorised ESAB service technician. Use only ESAB original spare
and wear parts.
WARNING!
Risk of personal injury.
• Disconnect the mains connection cable before starting any maintenance work.
• Use necessary personal safety equipment.
Perform maintenance work as follows:
Change the filter cartridge (and optional HEPA-filter) if necessary.
Check the airflow capacity of the unit.
Check that the fume extractor hose is not damaged. If necessary, change the
hose.
Check that the hose to the fan inlet is not damaged. If necessary, change the
hose.
Check that no objects have been caught on the guard net on the fan inlet.
If necessary, adjust the fume extractor links.
If necessary, tighten the arm profile bolts, see the * symbols in Figure 7.
Check that the mains connection cable and the fan motor cable are not worn or
damaged.
Check that the eccentric locks tighten the filter casing properly. Adjust the
eccentric locks if necessary.
9

Recycling

The product has been designed for component materials to be recycled. Its different
material types must be handled according to relevant local regulations. Contact the
distributor or ESAB if uncertainties arise when scrapping the product at the end of its
service life.