7) Click the button "OK". The available capacity and the
available recording time will be shown. To make further
settings, proceed with step 2) in chapter 6.4, or, to termi-
nate the setup, click "Cancel" and then click "OK" when
the message "Are you sure you want to cancel Startup
Wizard?" appears.
6.3 Status at first switch-on
1. Continuous recording of all channels to which a camera is
connected will start immediately, indicated by the symbol
R
(Record) in the camera image.
2. If there are channels to which no camera is connected, an
alarm signal will sound for 10 seconds (automatic recog-
nition of missing video signal).
3. When the hard disk is full, the oldest recordings will be
automatically overwritten (continuous recording).
4. The motion detection feature is switched on: When a
change of the image contents is recognized, the symbol
M
(Motion) will appear and an entry in the event list will
be made (date, time, camera channel).
5. The date and the time are not correct.
IMPORTANT: Make sure to update the date and the time
(chapter 6.4 or chapter 6.5). Otherwise, it will not be possible
to find recordings made at a specific point in time.
6.4 Startup Wizard
When the recorder is equipped with a formatted hard disk,
the "Startup Wizard" will be called up after switch-on
(
Fig. 6-1). The wizard will guide you through the required
settings to be made.
Note: If the wizard fails to appear:
1) Press the right mouse button to show the toolbar:
Fig. 6-12
2) Click the symbol
"Main Menu".
3) In the main menu, click "System" in the upper bar.
4) In the last line "Show wizard", tick-select the corresponding field.
5) Click "Save" in the lower right of the menu. The message "Save Para-
meters Successful" will appear. Click "OK" to close it.
6) In the main menu, click "Shutdown" in the upper bar. A new window
will appear; click "Reboot". After the restart, the "Startup Wizard"
will appear.
If you do not want to use the wizard, click "Cancel". You will
be asked if you want to terminate the wizard. Click "OK"
to confirm. For configuration of the recorder, please refer to
chapter 6.5 (next double page) which provides an overview
of all menus.
1) To configure the recorder with the wizard, click "Next".
The menu for setting the hard disk will appear:
HDD Management
No.
State
1
OK
Overwrite
Auto
Don't show this window next time.
Fig. 6-13 Settings for the hard disk
40
Free/Total
Free Time
Select
923G/931G
210Hour
Format HDD
×
Cancel
Previous
Next
2) The line at the top of the menu provides information with
regard to the hard disk. To set the overwrite mode, open
the pop-up menu: Click the symbol
Heading
No.
Number of the hard disk
State
Hard disk okay or unformatted
Free / Total
Available / total hard disk capacity
Free Time
Recording time still available (in hours)
Select
Column to select the hard disk to be formatted
Settings and functions
Overwrite
Auto
When the hard disk is full, the oldest record-
(factory setting)
ings will be overwritten and deleted.
No recordings will be overwritten and deleted.
When the hard disk is full, the message
OFF
"Warning Full" will appear and it will not be
possible to make any further recordings.
1 Day
Recordings can be overwritten after the
3 Days
storage time selected. When the hard disk is
full earlier, it will not be possible to make any
90 Days
further recordings.
Button to format the hard disk selected in the
Format HDD
column "Select"
3) When the hard disk settings have been made, click "Next".
The menu for the network settings will appear.
Network Configuration
PPPoE
DHCP
Client Port 09000
IP Address
192.168.001.100
Subnet Maske
255.255.255.000
Gateway
192.168.001.100
DNS1
192.168.001.100
DNS2
008.008.008.008
UPNP Disable
Don't show this window next time.
Fig. 6-14 Network settings
4) If the recorder is not connected to a network, click "Next"
to go to the next menu and then continue with step 5.
For the network connection, the static setting is re-
commended. The following setting options are available:
Settings
With the option PPPoE, enter the user name
PPPoE
and the password supplied by the Internet
Point-to-Point Pro-
service provider and set the client port as well
tocol over Ethernet
as the HTTP port. It will then be possible to
(for DSL modems,
remotely access the recorder via the IP address
hardly used any-
captured after a domain name and the HTTP
more)
port have been registered.
With the option DHCP, the router will auto-
DHCP
matically assign an IP address to the recorder.
Dynamic Host Con-
However, the IP address assigned can be
figuration Protocol
different with each restart. Consequently, port
(factory setting)
forwarding is required for remote access to
the recorder (set UPNP to "Enable").
Static
With the option "Static", enter the correct IP
(recommended
address, subnet mask, gateway and DNS.
setting)
3G
This option is available for older mobile
mobile phone
phones and is hardly used anymore.
system
When the router supports the UPnP function
and when UPNP has been set to "Enable",
UPNP
the recorder will automatically send the port
Universal Plug
numbers to the router. For the recommended
and Play
setting "Static", the factory setting "Disable"
should be used.
.
Static
3G
HTTP Port 00080
×
Cancel
Previous
Next

Publicité

loading