APPLICABLE CONTROLS
When using the equipment for the first time, the remote controller will not accept any commands for a short
period of time.
• Automatic address
• While automatic addressing no operations can be performed on the remote control.
• Automatic addressing will take a maximum duration of 10 minutes (generally 5 minutes).
• Upon turning on the unit after completion of automatic addressing, a maximum period of
10 minutes (generally 3 minutes) are required prior to the start up operation of the outdoor unit.
All indoor units are shipped from factory as standard. Change if necessary.
To change the setup use the main remote controller (wired remote controller).
* The setup change for wireless remote controller, sub remote controller or a unit without a controller (Centrally
controlled.) is not possible. In such cases, temporarily install a separate main remote controller.
Applicable control setup
Basic operation procedure for setup change
Change the setup while operation of the equipment is stopped.
(Be sure to stop the operation of a set.)
Procedure
SET
Push the
as shown in the figure.
Check that the displayed item code is [10].
• If the item code indicates any characters other than [10], push the
1
button to erase the display and retry the operation from the first step.
(For some time after the
of the remote controller cannot be accepted.)
(In a group control, the firstly displayed
indoor unit No. becomes the center unit.)
Each time the
Select the indoor unit that requires a change to the setup.
2
During this time the indoor unit that is selected can be
confirmed as the louver and fan will be operated.
TEMP.
Using
3
Using the
4
SET
Push the
complete.
5
• To change the setup of an indoor unit that is not selected, restart operation from Procedure
• To change to a different setup within the selected indoor unit, restart operation from Procedure
Pushing the
When the setup is finished, push the
Pushing the
6
normal stopped status.
(For a period of time after the
controller will not accept any commands.)
NOTIFICATION
CL
TEST
,
and
buttons simultaneously for 4 seconds or more, after a while, the display part flashes
TEST
button has been pushed, the operation
UNIT
button is pressed, the indoor unit No. in the group control is displayed consecutively.
the buttons, select the item code [
TIME
buttons, select set data [
button. During this time, if the display changes from flashing to permanently on, the setup is
CL
button clears the set up contents which has been set. In this case, restart from Procedure
TEST
TEST
button deletes the display and returns the status to the
TEST
button has been pushed, the remote
6
1
6
Description
**
].
****
].
button. (The setup is configured.)
18
CODE No.
UNIT No.
R.C.
No.
TEMP.
ON / OFF
TIMER SET
FAN
MODE
TIME
SWING/FIX
VENT
FILTER
RESET TEST
SET CL
UNIT
TEST
SETTING
UNIT No.
R.C.
(* The display changes according
to the indoor unit model.)
∗∗ ∗
UNIT No.
∗ ∗∗
R.C.
2
3
2
5
CODE No.
No.
∗∗
CODE No.
No.
.
3
.