Instruction Manual Crimping Tool
EK 35/4-L
4.4 Service and maintenance instruction
For every day service the tool has to be cleaned and dried after each use. The battery cartridge and the charging unit
have to be protected against humidity and dust.
The electric-hydraulic unit is equipped with a controller enabling the user to see when the next service is due by
fl ashing for 20 sec. at the end of a working cycle.
The unit must be sent to an authorized service center (ASC) after reaching 10.000 cycles or at the latest after one
year. During this service worn out parts will be exchanged, safety relevant components checked and possibly repla-
ced pre cautiously. This provision serves your safety and avoids failures through fatigue.
Attention
Maintain power tools thoroughly. Check for functionality or jamming of moving parts, breakage of parts and
any other condition that may affect the power tools operation.
Attention
Do not damage the seals of the tool. If the seal is damaged the warranty claim is void.
Attention
Have damaged parts repaired by a qualifi ed expert or by a Klauke ASC before use.
5.
Troubleshooting
a.) Constant fl ashing/indicating of the red LED (pic 1.3) or the occurence of an acustical warning signal.
see table 1. If the failure can not be resolved through the action recommended in table 1 return the tool to the
nearest service center (ASC).
b.) The tool loses oil.
Return the unit to the manufacturer. Do not open it and damage the seal of the tool.
c.) The red LED fl ashes 3x and simultaneously 3 acoustic warning signals occure (see table 1).
Serious fault! If this fault occures repeatedly return the unit to an Autorized Service Center (ASC). Do not open
it and damage the seal of the tool.
In case of a one time occurence the connector has to be pressed a second time.
HE.14064_B © 12/2010
6
GB