Télécharger Imprimer la page

RIB AA38004 Mode D'emploi page 33

Avec l1/r4-crx
Masquer les pouces Voir aussi pour AA38004:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A - CONNEXIONS
IT IS COMPULSORY TO SET THE DIP
13 OF THE CONTROL PANEL IN THE ON
POSITION.
T1
T2
JA
T T R
S
T
N
U
V
W
3-PHASE LINE
400V + N
MOTOR
3 P
PTO
J1
L1 - N
230 Vac 50/60Hz power supply (120 Vac 60Hz upon request)
J2
Flashing light (max 40 W )
U
Motor common connection
V-W
Motor phases and capacitor connections
J3
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Gate open state (24 Vdc 3 W max)
COM A+
Common contacts / Positive 24 Vdc
J4
A+ COM
+ 24 Vdc accessories power supply / Common contacts
A-
- 24 Vdc accessories power supply
A+ TEST
+ 24 Vdc photocells self-test power supply
J5
COM A+
Common contacts / Positive 24 Vdc
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
J6
COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOT 1
Photocells contact 1 (NC)
PHOT 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
J8
J7
J6
J5
J4
J3
J2
J1
F1
INNER THERMAL OVERLOAD CUT-OUT SWITCHES (per CEI
2-3/IEC 34-1)
The electrical protections on the SUPER 6000 motor power
line may not be sufficient to protect against overloads. If
PROG
the cooling conditions worsen, the motor overheats but
the electrical conditions do not change, which inhibits line
protections. Installing the bimetallic device PTO on the L1/
J11
R4-CRX control panel solves this problem.
J12
J13
J14
J15
J16
J17
J7
COM A+
Common contacts / Positive 24 Vdc
LIMIT SWITCH
Limit switches that cuts OFF the motor
J8
PROBE
IS NOT AVAILABLE
J9
ENCODER
IS NOT AVAILABLE
J10
RS485 termination of J11
J11
APP+
Connector for APP+ card
J12
APP
Connector for APP card
J13
SERIAL COM /
Connector for serial connection
SYNC
J14
-
-
J15
RADIO
Connector for radio module ACG8069
J16
RADIO
Connector for radio receiver RIB, 24 Vdc supply
J17
433 MHz Radio antenna
PROG.
Programming button
Trimmer for automatic closing time adjustment (DISABLED
TCA
DEFAULT AND DL11 LED OFF)
LOW SP
IS NOT AVAILABLE
TORQUE
IS NOT AVAILABLE
F1
T5A
Fuse for motor protection
T1 - T2 T
POWER RELAYS FOR THE COMMAND OF THE MOTOR
JA
R-N
SINGLE PHASE POWER SUPPLY - NEUTRAL
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
33
This is a NC electromechanical device that
opens when the threshold temperature is
reached; it automatically resets when the
temperature falls below the threshold
level.
G
B

Publicité

loading

Ce manuel est également adapté pour:

Super 6000