ENTRETIEN
[
HYDROLINK
BATTERY WATERING SYSTEM
(OPTION)
The following instructions are for models equipped
with the HydroLINK battery watering system
option.
The optional HydroLINK battery watering system
provides a safe and easy way to maintain the
proper electrolyte levels in your batteries. It is
designed exclusively for Trojan
batteries.
Check the battery watering system hoses and
connections for damage or wear after every 100
hours.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
1. Lift the operator seat open and engage the
seat support.
2. Fully charge batteries prior to using the
battery watering system. Do not add water to
batteries before charging, the electrolyte level
will expand and may overflow when charging.
See CHARGING THE BATTERIES
(OFF−BOARD CHARGER) or CHARGING
THE BATTERIES (ON−BOARD CHARGER).
64
®
wet/lead−acid
3. After charging batteries, check the battery
electrolyte level indicators located on the
battery covers. If the level indicator is white
add water as described in the following
instructions. If the level indicators are black
the electrolyte is at the correct level, no water
is required.
4.. Locate the battery fill hose coupler inside the
battery compartment. Remove the dust cap
and connect the hand pump hose.
5. Submerge the other end of the hand pump
hose into a bottle of distilled water.
Distilled
Water