Dip switch settings
■ SW500
1. When outputting the Indoor unit on/off
ON
1
2
3
4
5
6
Setting required
2. When outputting the Indoor unit error/ok
ON
1
2
3
4
5
6
Setting required
■ SW501 and SW502 do not have to be set.

5. Dip Switch Details

■ SW500 - Input/Output Mode Settings
SW No.
Functions
No. 1
Not in use
No. 2
HA terminal (CN504) input switch
No. 3
HA terminal (CN504) output switch
No. 4
Remote control (CN591) mode switch 1
No. 5
Remote control (CN591) mode switch 2
No. 6
Remote control (CN591) mode switch 3
No. 7
Relay, extermination output mode switch
No. 8
Turn on/off with power option
The relay is ON when the unit is running, and OFF when it is not.
7
8
The relay is ON when an error has occurred, and OFF when the unit is functioning
properly.
7
8
OFF
Set to OFF
Pulse input
Static mode
See the next page
ON/OFF output
Turn ON/OFF with
power: No
(unit remains OFF
when the source
power is turned ON)
ON
Be sure to set these to OFF (When set to OFF, the
unit cannot communicate with the air conditioner).
Continuous input
There is a switch between TC1 and 2 input on the
TB571.
Dynamic mode
See the next page
ERROR/OK output
When there is a problem while the unit is running,
it will output a relay ON signal.
When the Auto Restart function on the air condi-
Turn ON/OFF with
tioner itself is set to ON, be sure to set these to
power: Yes
OFF.
(Returns the unit to
the same status (ON/
OFF) as prior to
power off.)
Comments
9