Remove the Door (cont.)
Raise and latch the door.
Have the second installer hold the door up and position a 2x4 under the door, with the bottom end
of the 2x4 positioned on the subfloor (not the drip tray).
CAUTION: Risk of personal injury and product damage. When the screw is removed from the
roller assembly plate, friction is the only force holding the roller assembly in place. Make sure the
door is being held by a second person or a 2x4 when the plate is removed.
On the side of the door opposite the drain, carefully remove the screw nearest the rubber door stop
securing the cover plate and roller assembly on the bottom of the door. Take care not to strip the
screw heads.
Slide the roller assembly down 2" (5.1 cm) to 4" (10.2 cm). If it sticks, gently pry or tap the roller
assembly to help lower it.
Unplug the power cord from the inside of the door by reaching up into the recess that the plate
covered.
Remove the power cord from the door, then slide the roller assembly all the way down.
IMPORTANT! Do not cut the cable ties securing the power cord to the roller assembly.
NOTE: The power cord is held in place by a bracket at the base of the roller assembly. Do not remove the
bracket unless necessary.
Set the roller assembly aside with the power cord attached.
Remove the 2x4.
NOTE: The roller assembly on the drain side of the door will remain attached.
Squeeze the door handle and pivot the door out of the track on the side opposite the drain.
Remove the door and carefully set it aside.