Adjust roller
and mounting
bracket contact.
Pulley
Assembly
Lift and lower door several
times with one finger to
establish smooth travel.
1
Tighten
nut.
Adjust the bumper pads.
16. Adjust the Bath Door
All Installations
Check and Adjust the Door Movement
Move the bath door up and down several times with one finger. Check for uneven movement,
rubbing, or shaking.
If the door shimmies or racks, adjust one or both of the mounting brackets inward using the slots,
until they are snug against the rollers.
When properly adjusted the door should move up and down using one finger.
If there is rubbing or contact between the bath and door, adjust the door outward using the slots in
the pulley assembly.
Repeat until the door operates smoothly.
1128535-2-B
Mounting Bracket
Limit Switch
2
Adjust the limit switches.
Bumper
Latch Pin
Strike
Plate
Screw
28
Proper Bumper Adjustment
Improper Adjustment