Possible cause
The tightening torque of the centre bolt is
incorrect.
7.7
The motor operates at slow speed during or after the tool has been put into
water
/i
Possible cause
The electrical circuit has a temporary fault.
The tool operates in safe mode.
8
Maintenance
8.1
General
Proper preventive maintenance of the equipment preserves the operational safety and extends the life
of the equipment. For malfunctions or repair, always specify the model and serial number of the
equipment.
CAUTION
When performing maintenance activities, always comply with the relevant safety regulations.
Wear the prescribed personal protection equipment.
8.2
Dangerous substances
CAUTION
Used or leaked fluids, and any other products consumed during the activities,
must be collected and disposed of in an environmentally responsible way.
8.3
Maintenance materials
/i
Application
Steel parts
Hinge pins
Long-term preservation
Contact the Holmatro dealer for information on spare parts.
PCU50
All manuals and user guides at all-guides.com
Type of maintenance material
WD-40 preservative oil
Teflon lubricating oil
Tectyl ML from Valvoline
916.400.096_003
Solution
Tighten the bolt to 50 Nm.
Solution
Clean the tool fully. Refer to 6.4.4.
EN
Amount
As required
As required
As required
49