6.3.5
Environmental information
Under normal use, no leakage will occur. Therefore, there will be no contact with toxical substances
inside the battery pack.
Under normal use, no environmental hazard is present.
6.4
After use
6.4.1
Inspection
Check the battery level. Recharge the battery pack, if necessary. See section 3.6.2.
Check the tool for completeness, leaks and damage. Do not use the tool if it leaks or is damaged
and contact the Holmatro dealer.
Check the operation of the deadman's handle. The handle must return to the neutral position when
you release it.
Check that the carrying handle is firmly attached.
Inspect the blades. Replace them if the damage is considerable.
6.4.2
Shut down
Close the blades with the blade tips over each other to prevent injury. Do not fully close the blades
so that the tool can be stored without pressure.
Stop the tool.
Remove the battery pack and put it in the battery charger.
It is also possible to charge the battery on the tool with the on-tool charge cable.
A battery pack can be put on the battery charger. It can also be connected via the on-tool charge
cable. If these two functions are used, the battery pack on the tool is charged first.
6.4.3
Storing the battery pack
NOTICE
When the battery pack is not in use, it is advised to keep the battery pack connected to the
battery charger (connected to a power source) at all times. When the battery pack is full, the
battery charger automatically switches on and off at regular intervals to keep the battery
level at 100%.
Store the battery pack in a dry and well-ventilated area. The maximum storage temperature of 40 °C
(104 °F) may not be exceeded.
Make sure the equipment can not fall over during transport.
6.4.4
Cleaning and storage
NOTICE
If the tool has been used under water, a Holmatro Certified Technician must clean the tool as
soon as possible. To make sure that the tool operates correctly, it must be cleaned in less
than 1 week.
After normal use
1. Clean the tool and any accessories before storage.
2. Dry the tool if it was used in wet conditions. Apply a thin coat of preservative oil to the external steel
parts.
3. Store the tool in a dry and well-ventilated area.