Vortice ME Serie Livret D'instructions page 41

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
ENGLISH
0 sec.
T
A
45 sec.
6 min.
12 min.
T
B
18 min.
24 min.
60%
70%
U
R
80%
90%
Timer
Operat.
mode
Disabl. HCS
T
= time lag for switching on
A
T
= time lag for switching off
B
T
= automatic cycle time
C
U
= relative humidity
R
Table A
Speed
V1
V2
LL T
Factory settings
- appliance type (dip switch: mod.100 or 120: fig.18);
- switch-off delay (trimmer): full scale anticlockwise: 3 minutes (fig.19)
- 1 speed: position A of the jumper (fig.20).
Possible settings
- This model has 2 dip-switches. The position of switch 1 identifies the type of appliance (100 or 120: fig. 18) and MUST
keep the setting provided by the manufacturer. The setting of switch 2 has no effect whatsoever on the operation of the
appliance.
- Trimmer setting (fig.19). There is a trimmer on the PCB that enables adjusting the duration of the switch-off delay (from
3 to 20 minutes: clockwise = increase the delay, anticlockwise = decrease the delay).
- Jumper setting (fig.20). The motor has one operating speed: V. By appropriately setting the jumper as described in the
following table B it is possible to determine which of the two speeds Vmin and Vmax will be the actual operating speed
of the appliance.
LL T PIR
Factory settings
- appliance type (dip switch: mod.100 or 120: fig.18);
- switch-off delay (trimmer): full scale anticlockwise: 3 minutes (fig.19)
- 1 speed: position A of the jumper (fig.20).
Possible settings
- This model has 2 dip-switches. The position of switch 1 identifies the type of appliance (100 or 120: fig. 18) and MUST
keep the setting provided by the manufacturer. The setting of switch 2 has no effect whatsoever on the operation of the
appliance.
- Trimmer setting (fig.19). There is a trimmer on the PCB that enables adjusting the duration of the switch-off delay (from
3 to 20 minutes: clockwise = increase the delay, anticlockwise = decrease the delay).
- Jumper setting (fig.20). The motor has one operating speed: V. By appropriately setting the jumper as described in the
following table B it is possible to determine which of the two speeds Vmin and Vmax will be the actual operating speed
of the appliance.
Int. 1
Int. 2
OFF
--
ON
--
--
OFF
--
OFF
--
ON
--
ON
--
--
--
--
--
--
--
--
--
--
--
--
DIP switch
Int. 3
--
--
--
--
OFF
--
ON
--
OFF
--
ON
--
--
ON
--
OFF
--
ON
--
OFF
--
--
--
--
Jumper
Position A
MIN speed
MAX speed
Int. 4
Int. 5
--
--
--
--
--
--
ON
OFF
OFF
ON
--
--
Position B
MAX speed
MIN speed
Int. 6
--
--
--
--
--
--
--
--
--
--
OFF
ON
41