INSTALLATION INSTRUCTIONS
TEST RUN
Before completing a test run, make sure to complete all electrical safety checks and gas leak checks.
Confi rm that the unit's electrical system is safe and operating properly. Check all fl are nut connections and
confi rm that the system is not leaking.
Test Run Instructions
1. Connect power to the unit.
2. Press the ON/OFF button on the remote to turn the unit on.
3. Press the MODE button to scroll through the following functions:
• COOL - select lowest possible temperature
• HEAT - select highest possible temperature
4. Allow each function to run for 5 minutes and perform the following checks:
• No electrical leakage
• Unit is properly grounded
• All electrical terminals are properly covered
• Indoor and outdoor units are solidly installed
• All pipe connection points do not leak
• Water drains properly from the drain hose
• All piping is properly insulated
• Unit performs COOL function properly
• Unit performs HEAT function properly
• Indoor unit louvers rotate properly
• Indoor unit responds to the remote control
IMPORTANT: During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks
that were not present during the initial leak check. Take time during the test run to double check that all
refrigerant pipe connection points do not have leaks.
5. After the test run is successfully complete, use the remote control to return the unit to normal operating
temperature. Using insulation tape, wrap the indoor refrigerant pipe connections that were left
uncovered during the indoor unit installation process.
Test Run in Low Temperature
If the ambient temperature is below 17
control. In this instance, use the manual control button to test the COOL function.
1. Lift the front panel of the indoor unit and raise it until it clicks into place.
2. The manual control button is located on the right-hand side of the unit. Press it two times to select the
COOL function.
3. Perform test run as normal.
Disposal Guidelines
This appliance contains refrigerant and other potentially hazardous materials. When disposing of this
appliance, the law requires special collection and treatment. Do not dispose of this appliance as household
waste or unsorted municipal waste.
o
C (62.6 F), the COOL function will not run when using the remote
25