Electrical
Disconnect power before installing or servicing the pump.
Our pump is equipped with silicone blocked, tin coated 16 gauge (1.5 mm
Please follow the table below when extending the wires.
Recommended Wire Size
Total Wire Length (positive to pump to ground) - feet (meters)
0-6 ft
(0-1.8 m)
16 AWG
(1.5 mm
)
2
The electrical wiring, connections, and installation shall be in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
This pump must be fused as follow:
GPH (LPH)
360 (1362)
500 (1893)
800 (3028)
1100 (4164)
500 (1362)
800 (3028)
1100 (4164)
All potential sources of ignition located in spaces containing gasoline powered
machinery or gasoline fuel tank(s), or joint fitting(s), or other connection(s), between
components of a gasoline system, shall be ignition protected in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
The electrical wiring, connections, and installation shall be in accordance with the
requirements of ISO 10133, ABYC E-11, AC and DC Electrical Systems On Boats.
6- 10 ft
(1.8 - 3 m)
14 AWG
(2.5 mm
)
2
Volts Amps (Volts)
12
12
12
12
24
24
24
10 - 15 ft
(3 - 4.6 m)
(4.6 - 5.5 m)
12 AWG
(4 mm
)
2
12 Volts
2.1 (12)
1.6 (12)
3.4 (12)
3.7 (12)
24 Volts
1.0 (24)
1.7 (24)
1.9 (24)
3
15 - 30 ft
30 - 40 ft
(5.5 - 12.2 m)
10 AWG
(6 mm
)
(10 mm
2
Amps
Fuse Size
(Volts)
2.4 (13.6)
1.8 (13.6)
4.3 (13.6)
4.7 (13.6)
1.2 (27)
2.0 (27)
2.2 (27)
) wire.
2
8 AWG
)
2
4 A
4 A
7.5 A
7.5 A
3 A
4 A
4 A