Maintenance of the filter
• Always disconnect from the mains supply before carrying out any maintenance!
• Clean filter regularly, after first installation. If your pond is heavily polluted, the filter sponge should initially be cleaned daily.
Remove the filter compartment cover (C-f) by simultaneously pressing the catch (C-g) on both sides and lifting the cover up.
• Take out the filter sponge and rinse with clean tap water.
• Activated carbon absorbs color and toxins from the water and therefore becomes saturated. Replace the filter sponge and the
filter media twice a season (more often if necessary), a Combi Clear Filter Media Set (art. 06020760 and art. 06020763) is available
from your SuperFish dealer.
Maintenance of the pump and UVC-unit
• Check monthly the operation of the UV lamp via the light indicator on the cover (C-d).
• Always disconnect from the mains supply before carrying out any maintenance!
• For maintenance of the pump and UVC, first loosen and remove the spray pipe (C-a).
Press the catch (C-h) of the front cover on both sides and lift the cover up.
• The pump and the UVC-unit are connected to each other by a 90° bend, loosen one of the swivels (D-i) to disconnect the pump
from the UVC.
• Your pump needs regular cleaning. There is no warranty on failures due to dirty pumps and scale build up inside the pump caused
by improper maintenance.
• Depending on usage the rotor of your pump can get worn out and damaged, this is normal, new rotors can be purchased at your
dealer.
• The UVC device should be cleaned twice a year. As soon as algae growth increases, check the UVC and UV-lamp and clean or
exchange as needed.
• The lamp is hot, wait 10 minutes after switch off before opening the unit.
• Slide the red switch lock (E-j) to unlock the unit head and housing.
• Turn the unit head counter-clockwise against the stop then carefully pull it out of the housing (E-k).
• Loosen the screw (F-l), remove the locknut (F-m). Remove the quartz glass including the gasket by a slight rotary movement (F-n).
• Clean the quartz glass outer face with SuperFish UVC Pump & Clean carefully and check for damage.
• Remove the UV-lamp together with UV-tube clip (G-o) and tube protection ring (G-p) and remove the O-ring (G-q) from the unit
head. Clean the unit head and make sure that it's dry, place a new O-ring if necessary.
• Replace the UV-lamp if necessary (recycling). Insert the (replacement) UV-lamp with a UV-tube clip and tube protection ring in
the fitting of the unit head.
• Insert the quartz glass with the gasket in the unit head, slide the locknut over the quartz glass and tighten it onto the unit head.
Place the screw back and tighten the locknut (H).
• Place the unit head with the fitted UV-lamp and quartz glass back into the housing. Turn it clockwise up to the stop and slide the
red switch lock to the housing (J).
• To avoid UVC overheating, switch off the UVC device when no water is flowing past it.
• In the winter season, when the system is not used, the Combi Clear filter should be removed to avoid the risk of freezing.
• The UV-lamp should be replaced yearly.
(Combi Clear 2000: SuperFish UV Clear PL-lamp 5 watt, G23-105 mm - Art. 06011005)
(Combi Clear 4000: SuperFish UV Clear PL-lamp 7 watt, G23-105 mm SP - Art. 06011013)
(Combi Clear 6000: SuperFish UV Clear PL-lamp 11 watt, G23-167 mm SP - Art. 06011017)
5